Faure FOA25601XK Bedienungsanleitung Seite 19

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 18
BUILDING IN
16
573
21548
min. 550
20
600
min. 560
558
589
114
594
595 +/-1
3
5
558
21548
min. 550
20
589
114
16
573
590
min. 560
594
3
5
595 +/-1
SECURING THE APPLIANCE TO THE
CABINET
A
B
ELECTRICAL INSTALLATION
The manufacturer is not responsible if
you do not follow the safety
precautions from the Safety chapters.
This appliance is supplied only with a main cable.
CABLE
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F, H05
V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total power
on the rating plate. You can also refer to the table:
Total power (W)
Section of the cable
(mm²)
maximum 1380 3 x 0.75
maximum 2300 3 x 1
maximum 3680 3 x 1.5
The earth cord (green / yellow cable) must be 2 cm
longer than phase and neutral cables (blue and
brown cables).
ENERGY EFFICIENCY
PRODUCT FICHE AND INFORMATION ACCORDING TO EU 65-66/2014
Supplier's name Faure
19